EasyManua.ls Logo

Siemens SINAMICS G120D CU240D-2 DP - p10046 SI Motion F-DO feedback signal input activation; SI F­DO FS act; p10047 SI Motion F-DO test stop mode (processor 1); SI F­DO testmodeP1; r10049 SI Motion F-DI monitoring status (processor 1); SI F­DI status P1

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G120D
486 List Manual (LH14), 01/2016, A5E33842313
Description: Activates the readback input for the safety digital output (F-DO)
The test mode for the particular safety digital output is set in p10047.
Dependency: Refer to: p10001, p10003, p10007, p10047
Note: The test stop is only performed if the safety output of the Control Unit is being used (see p10042).
Description: Sets the test stop mode for the safety digital output (F-DO)
Value: 2: Test mode 2 read back F-DO in DI (relay circuit)
3: Test mode 3 read back F-DO in DI (actuator with feedback signal)
4: Test mode 4 evaluation of two internal diagnostic signals
Dependency: Refer to: p10001, p10003, p10007, p10046
Note: The test stop is only performed if the safety output is being used (see p10042).
Description: Displays the monitoring status of the fail-safe digital inputs (F-DI).
The F-DIs that are being used by the Safety Integrated functions are displayed.
If the module used has fewer than 3 F-DIs, "Freely available" is displayed for the F-DIs which are not in use.
Dependency: p10006 / p10106
p10022 / p10122
p10023 / p10123
p10026 / p10126
p10030 / p10130
p10031 / p10131
Refer to: r10149
p10046 SI Motion F-DO feedback signal input activation / SI F-DO FS act
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Test F-DO 0 Test active No test -
p10047 SI Motion F-DO test stop mode (processor 1) / SI F-DO testmodeP1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
2 4 4
r10049 SI Motion F-DI monitoring status (processor 1) / SI F-DI status P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 F-DI 0 Safety monitored Freely available -
01 F-DI 1 Safety monitored Freely available -
02 F-DI 2 Safety monitored Freely available -

Table of Contents

Related product manuals