EasyManua.ls Logo

Siemens SINAMICS G120D CU240D-2 DP - 2.4.4 Connector outputs (CO)

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
581
2 Parameters
2.4 BICO parameters (connectors/binectors)
r20356 BO: MFP 2 output Q / MFP 2 output Q
r20361 BO: MFP 3 output Q / MFP 3 output Q
2.4.4 Connector outputs (CO)
Product: SINAMICS G120D, Version: 4707900, Language: eng, Type: CO
r0021 CO: Actual speed smoothed / n_act smooth
r0025 CO: Output voltage smoothed / U_outp smooth
r0026 CO: DC link voltage smoothed / Vdc smooth
r0027 CO: Absolute actual current smoothed / I_act abs val smth
r0032 CO: Active power actual value smoothed / P_actv_act smth
r0034 CO: Motor utilization thermal / Mot_util therm
r0035 CO: Motor temperature / Mot temp
r0036 CO: Power unit overload I2t / PU overload I2t
r0037[0...19] CO: Power unit temperatures / PU temperatures
r0039[0...2] CO: Energy display / Energy displ
r0042[0...2] CO: Process energy display / Proc energy disp
r0060 CO: Speed setpoint before the setpoint filter / n_set before filt.
r0061[0...2] CO: Actual speed unsmoothed / n_act unsmoothed
r0062 CO: Speed setpoint after the filter / n_set after filter
r0063[0...2] CO: Speed actual value / n_act
r0064 CO: Speed controller system deviation / n_ctrl sys dev
r0066 CO: Output frequency / f_outp
r0067 CO: Output current maximum / I_outp max
r0068[0...1] CO: Absolute current actual value / I_act abs val
r0069[0...8] CO: Phase current actual value / I_phase act val
r0070 CO: Actual DC link voltage / Vdc act val
r0072 CO: Output voltage / U_output
r0074 CO: Modulat_depth / Mod_depth
r0075 CO: Current setpoint field-generating / Id_set
r0076 CO: Current actual value field-generating / Id_act
r0077 CO: Current setpoint torque-generating / Iq_set
r0078 CO: Current actual value torque-generating / Iq_act
r0079 CO: Torque setpoint / M_set
r0080[0...1] CO: Torque actual value / M_act
r0081 CO: Torque utilization / M_Utilization
r0082[0...2] CO: Active power actual value / P_act
r0083 CO: Flux setpoint / Flex setp
r0084[0...1] CO: Flux actual value / Flux act val
r0087 CO: Actual power factor / Cos phi act
r0094 CO: Transformation angle / Transformat_angle
r0289 CO: Maximum power unit output current / PU I_outp max
r0479[0...2] CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1
r0481[0...2] CO: Encoder status word Gn_ZSW / Enc Gn_ZSW
r0482[0...2] CO: Encoder actual position value Gn_XIST1 / Enc Gn_XIST1
r0483[0...2] CO: Encoder actual position value Gn_XIST2 / Enc Gn_XIST2
r0485[0...2] CO: Measuring gear encoder raw value incremental / Enc raw val incr
r0486[0...2] CO: Measuring gear encoder raw value absolute / Enc raw val abs
r0497[0...2] CO: Encoder diagnostic signal double word / Enc diag DW
r0498[0...2] CO: Encoder diagnostic signal low word / Enc diag low word
r0499[0...2] CO: Encoder diagnostic signal high word / Enc diag high word
r0586 CO: Measuring probe speed actual value / MT n_act
r0587 CO: Measuring probe measuring time measured / MT t_meas measured
r0588 CO: Measuring probe pulse counter / MT pulse counter

Table of Contents

Related product manuals