Siemens SINAMICS G120D CU240D-2 DP - p5606[0...1] Pe energy-saving mode time of maximum stay; Pe t_max_stay; p5611 Pe energy-saving properties general; Pe properties gen; p5612[0...1] Pe energy-saving properties mode-dependent; Pe properties mod; r5613.0...1 CO;BO: Pe energy-saving active;inactive; Pe save act;inact

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G120D
416 List Manual (LH14), 01/2016, A5E33842313
Note: It is not permissible that the value is less than the sum of the "energy-saving mode transition time" and the "operating
state transition time" (system properties).
Pe: PROFIenergy profiles
Description: Sets the time of maximum stay for the energy-saving mode.
Index: [0] = Mode 1
[1] = Reserved
Note: Pe: PROFIenergy profiles
Description: Sets the general properties for energy-saving.
Note: Pe: PROFIenergy profiles
PROFIdrive state S4: operation
Description: Sets the mode-dependent properties for energy-saving.
Index: [0] = Mode 1
[1] = Reserved
Note: Pe: PROFIenergy profiles
Description: Display and binector output for the state display PROFIenergy energy saving active or inactive.
p5606[0...1] Pe energy-saving mode time of maximum stay / Pe t_max_stay
CU240D-2_PN
CU240D-2_PN_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2381
Min Max Factory setting
0 [ms] 4294967295 [ms] 4294967295 [ms]
p5611 Pe energy-saving properties general / Pe properties gen
CU240D-2_PN
CU240D-2_PN_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2381, 2382
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Inhibit PROFIenergy control commands Yes No -
01 Drive initiates OFF1 when transitioning to
energy-saving mode
Yes No -
02 Trans to energy-saving mode from
PROFIdrive state S3/S4 poss
Yes No -
p5612[0...1] Pe energy-saving properties mode-dependent / Pe properties mod
CU240D-2_PN
CU240D-2_PN_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - [0] 0110 bin
[1] 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Reserved Yes No -
01 Shutdown digital outputs Yes No -
02 Shutdown encoder supply Yes No -
r5613.0...1 CO/BO: Pe energy-saving active/inactive / Pe save act/inact
CU240D-2_PN
CU240D-2_PN_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2382
Min Max Factory setting
- - -