SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
575
2 Parameters
2.4 BICO parameters (connectors/binectors)
p2080[0...15] BI: Binector-connector converter status word 1 / Bin/con ZSW1
p2081[0...15] BI: Binector-connector converter status word 2 / Bin/con ZSW2
p2082[0...15] BI: Binector-connector converter status word 3 / Bin/con ZSW3
p2083[0...15] BI: Binector-connector converter status word 4 / Bin/con ZSW4
p2084[0...15] BI: Binector-connector converter status word 5 / Bin/con ZSW5
p2103[0...n] BI: 1st acknowledge faults / 1st acknowledge
p2104[0...n] BI: 2nd acknowledge faults / 2nd acknowledge
p2105[0...n] BI: 3rd acknowledge faults / 3rd acknowledge
p2106[0...n] BI: External fault 1 / External fault 1
p2107[0...n] BI: External fault 2 / External fault 2
p2108[0...n] BI: External fault 3 / External fault 3
p2112[0...n] BI: External alarm 1 / External alarm 1
p2116[0...n] BI: External alarm 2 / External alarm 2
p2117[0...n] BI: External alarm 3 / External alarm 3
p2144[0...n] BI: Motor stall monitoring enable (negated) / Mot stall enab neg
p2148[0...n] BI: RFG active / RFG active
p2200[0...n] BI: Technology controller enable / Tec_ctrl enable
p2220[0...n] BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
p2221[0...n] BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
p2222[0...n] BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
p2223[0...n] BI: Technology controller fixed value selection bit 3 / Tec_ctrl sel bit 3
p2235[0...n] BI: Technology controller motorized potentiometer raise setpoint / Tec_ctrl mop raise
p2236[0...n] BI: Technology controller motorized potentiometer lower setpoint / Tec_ctrl mop lower
p2286[0...n] BI: Hold technology controller integrator / Tec_ctr integ hold
p2290[0...n] BI: Technology controller limiting enable / Tec_ctrl lim enab
p2508[0...3] BI: LR activate reference mark search / Ref_mark act
p2509[0...3] BI: LR activate measuring probe evaluation / MT_eval act
p2510[0...3] BI: LR selecting measuring probe evaluation / MT_eval select
p2511[0...3] BI: LR measuring probe evaluation edge / MT_eval edge
p2512[0...3] BI: LR pos. actual value preprocessing activate corr. value (edge) / ActVal_prepCorrAct
p2514[0...3] BI: LR activate position actual value setting / s_act setting act
p2549 BI: LR enable 1 / Enable 1
p2550 BI: LR enable 2 / Enable 2
p2551 BI: LR setpoint signal fixed / Mess setp fixed
p2552 BI: LR signal travel to fixed stop active / Signal TfS act
p2553 BI: LR signal fixed stop reached / Signal fixed stop
p2554 BI: LR signal traversing command active / Sig trav_cmnd act
p2568 BI: EPOS STOP cam activation / STOP cam act
p2569 BI: EPOS STOP cam minus / STOP cam minus
p2570 BI: EPOS STOP cam plus / STOP cam plus
p2575 BI: EPOS jerk limiting activation / Jerk limit act
p2577 BI: EPOS modulo correction activation / Modulo corr act
p2582 BI: EPOS software limit switch activation / SW lim sw act
p2589 BI: EPOS jog 1 signal source / Jog 1 S_src
p2590 BI: EPOS jog 2 signal source / Jog 2 S_src
p2591 BI: EPOS jogging incremental / Jog incr
p2595 BI: EPOS referencing start / Ref start
p2596 BI: EPOS set reference point / Set ref_pt
p2597 BI: EPOS referencing type selection / Ref_typ select
p2604 BI: EPOS search for reference start direction / Srch for ref dir
p2612 BI: EPOS search for reference reference cam / Ref_cam
p2613 BI: EPOS search for reference reversing cam minus / Rev minus
p2614 BI: EPOS search for reference reversing cam plus / Rev plus
p2625 BI: EPOS traversing block selection bit 0 / Trav_blk sel bit 0
p2626 BI: EPOS traversing block selection bit 1 / Trav_blk sel bit 1