5. PARAMETERS
5 - 19
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P
S
T
PA13
*PLSS
Command
pulse input
form
Table 5.3 Command input pulse train form selection
Setting
value
Pulse train form
Forward rotation
(positive direction)
command
Reverse rotation
(negative direction)
command
_ _ 1 0
Negative logic
Forward rotation
pulse train
(positive direction
pulse train)
Reverse rotation
pulse train
(negative direction
pulse train)
NP
PP
_ _ 1 1
Signed pulse train
PP
L
H
NP
_ _ 1 2
A-phase pulse
train
B-phase pulse
train
PP
NP
_ _ 0 0
Positive logic
Forward rotation
pulse train
(positive direction
pulse train)
Reverse rotation
pulse train
(negative direction
pulse train)
NP
PP
_ _ 0 1
Signed pulse train
L
H
PP
NP
_ _ 0 2
A-phase pulse
train
B-phase pulse
train
PP
NP
Arrows in the table indicate the timing of importing pulse trains. A-phase and B-phase pulse trains are imported after
they have been multiplied by 4.