17 - 41
17Positioning mode (pushing operation)
17.10 Detailed list of parameters
17.10.1 Basic setting parameters ([Pr. PA_ _ ])
Refer to Chapter 7.2.1 for items not described in this chapter.
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
C
P
CL
PS
PA01
*STY
Operation mode
_ _ _ x
Control mode selection
Select a control mode.
0 to 5: Not used in positioning mode.
6: Positioning mode (point table method)
7: Positioning mode (program method)
8: Positioning mode (Equal division indexing method)
Point table method When using the pushing operation, set "6" positioning mode
(point table method).
0h
_ _ x _
Do not change this value.
0h
_ x _ _
Do not change this value.
0h
x _ _ _
For manufacturer setting
1h