16 - 243
16. POSITIONING MODE
No.
Symbol
Name
Initial
value
Unit
Operation
mode
Control
mode
Standard
CP
CL
PS
PC61
For manufacturer setting
0000h
PC62
0000h
PC63
0000h
PC64
0000h
PC65
0000h
PC66
LPSPL
Mark detection range + (lower three digits)
0
10
STM
[µm]
PC67
LPSPH
Mark detection range + (upper three digits)
0
10
STM
[µm]
PC68
LPSNL
Mark detection range - (lower three digits)
0
10
STM
[µm]
PC69
LPSNH
Mark detection range - (upper three digits)
0
10
STM
[µm]
PC70
*SNOM
Modbus-RTU communication station number setting
0
PC71
*COPF
Function selection C-F
0040h
PC72
*COPG
Function selection C-G
0000h
PC73
ERW
Error excessive warning level
0
PC74
For manufacturer setting
0000h
PC75
0000h
PC76
0000h
PC77
0000h
PC78
0000h
PC79
0000h
PC80
0000h
16.21.4 I/O setting parameters ([Pr. PD_ _ ])
POINT
The following parameter cannot be used in the positioning mode.
[Pr. PD03 Input device selection 1L]
[Pr. PD05 Input device selection 2L]
[Pr. PD07 Input device selection 3L]
[Pr. PD09 Input device selection 4L]
[Pr. PD11 Input device selection 5L]
[Pr. PD13 Input device selection 6L]
[Pr. PD17 Input device selection 8L]
[Pr. PD19 Input device selection 9L]
[Pr. PD21 Input device selection 10L]
[Pr. PD43 Input device selection 11L]
[Pr. PD45 Input device selection 12L]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSB2-T Series and is the answer not in the manual?

SMC Networks LECSB2-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSB2-T Series
CategoryDC Drives
LanguageEnglish