5. PARAMETERS
5 - 41
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P
S
T
PC13
TLC
Analog
torque/thrust
command
maximum
output
Set the output torque at the analog torque command voltage (TC = ±8 V) of +8 V on
the assumption that the maximum torque/thrust is 100.0%.
For example, set 50.0.
The maximum torque or thrust ×
50.0
100.0
is outputted.
When you input a command value of the maximum torque or more to TC, the value
is clamped at the maximum torque.
Setting range: 0.0 to 1000.0
100.0
[%]