5. PARAMETERS
5 - 65
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P
S
T
PF31
FRIC
Machine
diagnosis
function -
Friction
judgment
speed
Set a servo motor speed that divides a friction estimation area into high and low
during the friction estimation process of the machine diagnosis.
Setting "0" will set a value half of the rated speed.
When your operation pattern is under the rated speed, we recommend that you set
a half value of the maximum speed.
Forward rotation
direction
(Positive direction)
0 r/min
Operation pattern
[Pr. PF31] setting
Maximum speed in operation
Servo motor
speed
(Linear servo
motor speed)
Reverse rotation
direction
(Negative direction)
(0 mm/s)
Setting range: 0 to permissible speed
0
[r/min]/
[mm/s]
PF34
*SOP3
RS-422
communi-
cation
function
selection 3
_ _ _ x
For manufacturer setting
0h
_ _ x _
0h
_ x _ _
0h
x _ _ _
MR-PRU03 selection
Select this if using an MR-PRU03.
0: Disabled
1: Enabled
0h