12. ABSOLUTE POSITION DETECTION SYSTEM
12 - 27
(d) At the time of forced stop reset
210 ms after the forced stop is deactivated, the base circuit turns on, and RD turns on further 5 ms
after that, turns on. Always get the current position data using RD as the trigger before the position
command is issued.
1) When power is switched on in a forced stop status