EasyManuals Logo
Home>SMC Networks>DC Drives>LECSB2-T Series

SMC Networks LECSB2-T Series User Manual

SMC Networks LECSB2-T Series
945 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #688 background imageLoading...
Page #688 background image
16 - 188
16. POSITIONING MODE
(2) Timing chart
The following shows a timing chart after a program containing a "ZRT" command is selected.
The setting value of [Pr. PT08 Home position return position data] is used as the position address at the
home position return completion.
ON
OFF
MEND (Travel completion)
ON
OFF
CPO (Rough match)
ON
OFF
Servo motor speed
MD0 (Operation mode selection 1)
Forward rotation
0 r/min
Reverse rotation
ON
OFF
DOG (Proximity dog)
ZP
(Home position return completion)
ON
OFF
ON
OFF
ON
OFF
ST1 (Forward rotation start)
ST2 (Reverse rotation start)
3 ms or shorter
Home position return speed
Deceleration time constant
Creep speed
Travel distance after
proximity dog
+
Home position
shift distance
Home position return position data
Proximity dog
5 ms or longer
Acceleration time
constant
PED (Position end)
ON
OFF

Table of Contents