3. SIGNALS AND WIRING
3 - 36
Input device (Note 1)
Limit value status
Enabled torque limit value
TL1
TL
CCW power running/CW
regeneration
CW power running/CCW
regeneration
0
0
Pr. PA11
Pr .PA12
0
1
TLA
>
Pr. PA11
Pr. PA12
Pr. PA11
Pr. PA12
TLA
<
Pr. PA11
Pr. PA12
TLA (Note 2)
TLA (Note 3)
1
0
Pr. PC35
>
Pr. PA11
Pr. PA12
Pr. PA11
Pr. PA12
Pr. PC35
<
Pr. PA11
Pr. PA12
Pr. PC35 (Note 2)
Pr. PC35 (Note 3)
1
1
TLA
>
Pr. PC35
Pr. PC35 (Note 2)
Pr. PC35 (Note 3)
TLA
<
Pr. PC35
TLA (Note 2)
TLA (Note 3)
Note 1.
0: Off
1: On
2.
When "_ 2 _ _" is set in [Pr. PD33], the value set in [Pr. PA11] is applied.
3.
When "_ 1 _ _" is set in [Pr. PD33], the value set in [Pr. PA12] is applied.
(c) TLC (Limiting torque)
TLC turns on when the servo motor torque reaches the torque limited using the forward rotation
torque limit, reverse rotation torque limit or analog torque limit.