17-1. Sequence Operation Examples
17-1-1. Creating New Sequences
The operation example in this section shows how to create a new sequence in three steps
and store it to "Sequence Memory 0."
Creating a Sequence with the Keypad
(1) Press SEQ EDIT to change the Keypad to SEQ EDIT
mode.
(2) Press 9 (NEW), and then press ENTER to clear the
working memory.
(3) Create "Video A." Press 3 (ADD) to save "VIDEO A"
(the current control panel status) to Step 1.
(4) Create "Video B." Press 3 (ADD).
(5) Create "Video C." Press 3 (ADD).
Pressing the SEQ EDIT
button changes the Keypad to SEQ EDIT mode and enables the
following function buttons: NEW, INS, ADD, OVWR(OVERWRITE), DEL, PASTE, CUT,
COPY, INC, DEC, PLAY and STOP (See section 17-2-2. "SEQ EDIT Mode.")
Storing the Sequence
(1) Press SEQUENCE in the MEMORY block above the numeric keypad.
(2) Press STORE. The [SEQUENCE STORE] menu appears and displays the sequence
information in the working memory.
SEQUENCE:TOTAL STEP->3 :LOOP->OFF : 1/1
STORE :TOTAL TIME->60 :DIR ->NOR :
TOTAL STEP: Number of steps in the sequence
TOTAL TIME: Total playback time of the sequence
(in frames)
LOOP: Loop play On or Off
DIR: Playback direction of the sequence
(NOR: Normal, REV: Reverse)
(3) Press 0 . The sequence data in the working memory
is stored to "Sequence Memory 0."
If a Sequence Memory has stored data:
When storing a sequence, the number buttons on the Keypad (0 to 9) are changed to the
memory buttons that turn off if they have no data and turn on if they have stored data. To
store the current setup sequence to the button that has sequence data, press the memory
button (flashing) and then press the button. If another memory button is pressed before
pressing the button a second time, the sequence is saved to the former button.
If sequence data cannot be saved to the stored memory button, the sequence memory is
overwrite-
protected. In such case, clear the overwrite protection of the sequence memory.
(See section 17-3-1.)
SELECT / KEYPAD
5
2
RECALL
PASTE
4
1
6
3
DEC
SEQUENCEEVENTWIPE MACRO
CON TROL
MEMORY
MENU USER BUTTON COPY/SWAP SEQ EDIT
987
ATTACH
INC
MENU
COPY
STILL MATT
SWAP NEW
FILE
INS
KEY4KEY3KEY2KEY1
DETTACH
ADDDELCUTPLAY
+/-
CLE AR
WIPE
STOP
0
COPY
STO RE
ENTER
OVWR
SELECT / KEYPAD
5
2
RECALL
PASTE
4
1
6
3
DEC
SEQUENCEEVENTWIPE MACRO
CON TROL
MEMORY
MENU USER BUTTON COPY/SWAP SEQ EDIT
987
ATTACH
INC
MENU
COPY
STILL MATT
SWAP NEW
FILE
INS
KEY4KEY3KEY2KEY1
DETTACH
ADDDELCUTPLAY
+/-
CLE AR
WIPE
STOP
0
COPY
STO RE
ENTER
OVWR

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FOR-A HVS-390HS and is the answer not in the manual?

FOR-A HVS-390HS Specifications

General IconGeneral
BrandFOR-A
ModelHVS-390HS
CategorySwitch
LanguageEnglish

Related product manuals