EasyManua.ls Logo

iPECS UCP600 - Page 155

iPECS UCP600
721 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual Issue 2.5
141
Table 4.4.5.1-1 SYSTEM ATTRIBUTES
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
Default Web
Language
The user can select the display language used in the Web
pages. Either English or the “Local” language can be selected.
Note the “Local Language” must be entered in the Multi-
Language file in the Maintenance section.
English, Local language
Refer to
description
English
No Range Load
Limit on Web
Admin
OFF: Limited index range will be accepted (e.g. 1-100)
ON: No limitation of table index (e.g. 221, 222, 270, etc)
OFF/ON
ON
Forward
limitation by
caller COS
Caller(internal station) call to a station offnet forwarded. It can be
forwarded by caller COS if it's ON.
OFF/ON
OFF
No CLI Call Log
Leave system Call log even though there is no CLI information if
it is ON. Otherwise, the Call log is not left.
OFF
ON
OFF
Remote VM
Forward Access
If the value is ON, the Call Forwarding settings from remote
access are enabled. If the value is OFF, the Call Forwarding
settings from remote access are disabled.
OFF
ON
ON
DB Backup to
USB monthly
The system downloads the database to USB periodically.
The user can access, copy and delete files on a USB drive via
web admin. So you can back up DB by choosing the specific
date for Monthly or Weekly.
vUCP/eMG100 is not available for this feature.
N/A,
1,
15
N/A
DB Backup to
USB weekly
N/A,
Mon ~ Sun.
N/A
SLT Line Monitor
SLT line supervision is to be supported to periodically check the
line connection/disconnection as programmed - daily or
programmed time. When the line is disconnected, alarm
call/message notification is provided to pre-defined destinations
like other alarms. The system will send e-mail notifications
according to "Common SMTP Attributes" and "Alarm Attributes."
This is to provide more reliability for mission-critical services for
hospitality or health care solutions (i.e., bath alarms using the
SLT line).
OFF
ON
OFF
SLT Line Monitor
Conditions
Normal SLT service is not available during the detection
period since the detection takes several seconds.
The Ringer test determines the presence of appropriate
ringer terminations on the line. The measured impedance
must be within the defined limits: 1.4 kΩ (5 REN) ~ 40 kΩ
(0.175 REN). Otherwise, the test fails, which means that a
normal SLT device can be detected, but if a simple device
that does not provide the proper ringer impedance is
connected, we cannot detect it properly.
Supported system options: UCP/eMG80/100/800 with
Unified 2.1 software
Supported G/W & Boards: UCP-SLTM, UCP100 SLTU,
eMG80/100/800 SLIB
OFF
ON
OFF

Table of Contents

Related product manuals