Table 4.4.5.28-1 SYSTEM TIMERS
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
Flex DID Timer
The system will receive DID digits for this timer.
After the timer expires, the system will use the last 2 to 4 digits
received as DID digits.
01~99
(100 msec)
10
R2 Out Manage
Timer
Reserved for future usage for R2 timers.
01~50
(seconds)
14
R2 In Manage
Timer
Reserved for future usage for R2 timers.
01~50
(seconds)
14
R2 Disappear
Timer
Reserved for future usage for R2 timers.
01~50
(seconds)
14
R2 Pulse Timer
Reserved for future usage for R2 timers.
01~30
(*20ms)
7
R2 Ready Timer
Reserved for future usage for R2 timers.
000~500
(*200ms)
7
Dial Tone Delay
Timer
Reserved for future usage for R2 timers.
01~30
(*20ms)
20
Wake Up Fail
Timer
At the expiration of this timer, the system will notify the Attendant
when a user does not respond to a Wake-up alarm.
00~99
20
VSF Cut Error
Tone Timer
This timer reduces the duration of Voice Messages in the built-in
Voice Mail to remove the error tone that the carrier may send
after disconnect.
00~90
(seconds)
0
On-Hook Auto
Idle Timer
When an iPECS IP or LDP Phone receives a disconnect
message or signal from the CO line, the phone goes idle after
this timer.
00~99
(seconds)
0
IP Watch Timer
When Local redundancy is implemented, both call servers may
attempt to be active should the LAN cable fail. To protects
against this “dual active” case, the system can periodically check
for an active backup module.
0~250
(1 sec.)
0
Prepaid Call
Drop Warning
Timer
When the Prepaid funds are exhausted, the user will receive a
warning tone indicating the call will be dropped after this timer
expires.
00-99
10
Emergency retry
timer
The system tries to make an emergency call according to the
CO access rule/Prefer CO/CO group if the system could not
seize a predefined emergency Co line within this timer.
00~99
(seconds)
0
Record Warning
Repeat Timer
If the record warning tone is set and this timer is set greater than
1, it works periodically when it’s recorded.
000~999
(seconds)
0
Error Tone Timer
This timer sets the duration for Error Tone.
5~180
(seconds)
30
Howling Tone
Timer
This timer sets the duration for Howling Tone.
0~180
(seconds)
30
VM Notify Play
Delay Over CO
Timer
When VM notification to the mobile uses an analog loop-start
Line, the system will treat the call as the answer after this timer
and play the new message prompt.
1~99
(1 sec.)
10

Table of Contents