EasyManua.ls Logo

iPECS UCP600 - Page 635

iPECS UCP600
721 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual Issue 2.5
194
4.3.6.20 System Timers I to III - PGMs 180-182
A number of timers can be assigned to control and affect many features and functions of the system. Refer to
Table 3.3.6.20-1 to Table 3.3.6.20-3 for a description of the timers and the input required.
PROCEDURE
SYSTEM TIMER 1
PRESS FLEX KEY (01-22)
Press the [PGM] button and dial:
- 180 for System Timers I
- 181 for System Timers II
- 182 for System Timers III
Press the Flex button for the desired Timer; refer to Table 3.3.6.20-1 ~3.
Us the dial pad to enable or disable the desired language prompts.
Press the [Save] button to store the data entry.
Use the dial-pad to enter the desired Timer data. Refer to Table 3.3.6.20-1~3.
Press the [Save] button to store the Timer data entry.
Table 3.3.6.20-1 SYSTEM TIMERS I (PGM 180)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE
DEFAULT
1
ATD RECALL TMR(min)
(00-60) : 01
Determines the amount of time the
attendant receives recall, after which the
system will disconnect the call.
00~60
minutes
01
2
CALL PARK TMR(sec)
(000-600) : 120
Determines the amount of time before a
parked call will recall the station that parked
the call.
000~600
seconds
120
3
CAMP-ON RECALL TMR(sec)
(000-600) : 030
When a call transfer is camped on, this
timer determines the amount of time before
the station receives a recall.
000~600
seconds
030
4
EX-HOLD RECALL TMR(sec)
(000-600) : 060
Determines the amount of time before a call
placed on exclusive hold will recall the
station.
000~600
seconds
060
5
I-HOLD RECALL TMR(sec)
(000-600) : 030
Determines the amount of time before a call
that is recalling the station will recall before
also recalling the attendant.
000~600
seconds
030
6
S-HOLD RECALL TMR(sec)
(000-600) : 030
Determines the amount of time before a call
placed on system hold will recall the
station.
000~600
seconds
030
7
TRANS RECALL TMR(sec)
(000-600) : 030
Determines the amount of time a
transferred call will ring at the receiving
station before recalling the station that
transferred the call.
000~600
seconds
030
8
ACNR DELAY TMR(sec)
(000-300) : 030
If the ACNR Pause Timer expires and no
CO Line is available for ACNR recall, the
delay timer sets the delay before ACNR
attempts to access a CO line. The retry
counter is not decremented by this action.
000~300
seconds
030

Table of Contents