196
Table 3.3.6.20-1 SYSTEM TIMERS I (PGM 180)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE
DEFAULT
21
ON HOOK IDLE TMR (sec)
(00-99) : 00
Phone (IP/DKTU) goes to idle after this
timer when the phone receives a
disconnect message or signal from the CO
line.
00~99
seconds
0
22
CALL REC REPEAT TMR(sec)
(000-999) : 000
If the record warning tone is set and this
timer is set greater than 1, it works
periodically when it’s recorded.
000~999
seconds
0
Table 3.3.6.20-2 SYSTEM TIMERS II (PGM 181)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE
DEFAULT
1
FWD NO ANS TMR(sec)
(000-600) : 015
When a user activates No-Answer
Forward, calls will ring for this duration
before the calls are forward. The Station
No-Answer Forward timer PGM 123 will
take precedence.
000~600
(seconds)
015
2
DID/DISA NO ANS(sec)
(000-255) : 000
A DID/DISA call to a station will forward to
the DID/DISA Destination assigned in
PGM 167 should this timer expire before
the call is answered.
000~255
(seconds)
000
3
VSF USR RECORD(sec)
(000-999) : 060
This timer sets the maximum duration
allowed for the User Greeting in the
system’s basic Voice Mail.
000~999
(seconds)
60
4
VSF VALID USER MSG(sec)
(0-9) : 4
This timer sets the minimum duration
allowed for a voice mail message in the
system’s basic VSF Voice Mail.
Messages shorter than this period are not
stored.
0~9
(seconds)
4
5
DOOR OPEN TMR(100ms)
(00-99) : 20
This timer sets the minimum contact
closure time required to activate the
contact assigned as a door open contact.
00~99
(100msec.)
20
6
ICM DIAL TONE TMR(sec)
(001-255) : 010
If a user goes off-hook on the Intercom
and takes no action for this timer, the user
will receive an error tone.
001~255
(seconds)
10
7
INTER DIGIT TMR(sec)
(01-20) : 05
This timer sets the maximum allowed time
between user dialed digits. At expiration,
the user will receive an error tone.
01~20
(seconds)
05
8
MSG REMINDER TONE(min)
(00-60) : 00
An iPECS Phone user will receive
periodic reminder tones of a message
waiting at intervals based on this timer.
00~60
(minutes)
00