Call logging (CL)
281
System functions and features as of R4.1
syd-0570/1.2 – R4.1 – 08.2016
8. 5. 1 Output types
The output type depends on who triggered the output. The output types are as follows:
ICC output type
• Output at user’s request, e.g. using a command on the operator console
• ICC counter readings and reports
Service output type
• Output at user’s request, e.g. using a command on the operator console
• System configuration data
• Event message list
CL output type
• Output triggered by the system (e.g. when call charges are incurred)
• OCL journal printouts (online)
• ICL journal printouts (online)
Event output type
• Output triggered by the system
• System events such as:
– Synchronization loss
– External message destination unobtainable
Number of output devices
Up to 4 printers or output devices can be connected to the system.
If only 1 output device is connected, it will carry out all the output jobs. In normal oper-
ation it handles the CL printer job (ICL and OCL output). If the output is triggered from
somewhere else the output type is altered at short notice. If a CL output job is followed
by an Event output job, the new job will be separated by a line of asterisks *. If the
printout of the new job is to begin on a new page, a manual printer formfeed is to be
performed beforehand.
8. 6 Printer faults
If it is not possible to print on the printer for at least one minute (e.g.paper out), an
event message will be triggered in the communication server. If the interruption can be
remedied immediately, there are no further repercussions, as the call data is stored