9. 8. 2 Remote controlling features from outside the system
An integrated, external user A is dialled via a specially set call number into the commu-
nication server (see "Integrating mobile and external phones", page 61) and receives
the internal dial tone. Now he is treated like an internal user and can implement fea-
tures with the function code *06 for another authorised user B as described in the
chapter "Remote controlling features from within the system", page 474
. Moreover, like
any other internal user, he can implement a system-related feature. All functions are
available according to the feature overview in the Integrated mobile/ external phones
column (links to the feature overview, see Tab. 331
).
9. 8. 3 Time-controlled functions
In der system configuration ( =8x) up to 50 (Mitel 415/430) or up to 500 (Mitel 470)
Time controlled functions (*/# function codes) can be defined, to be executed once
at a particular time on a particular date. It is also possible to define recurring functions
to be executed at a particular time on a particular weekday or every weekday. The */#
function codes can be used for user-specific features or for settings applicable
throughout the system.
Unlike the control of features or the modification of configurations via the terminal,
time-controlled functions are not subject to the authorisations or to the digit barring that
apply to individual users.
Tab. 316 Examples of time-controlled functions:
Tip:
Inputs in the table can also accept Preparation (no execution) mode. Inputs can thus be deacti-
vated without being erased.
ID Name Function Mode
Start
day
Stop
day
Execution
date / time
Switch
group
assign-
ment
Meaning
1Forwarding
of manager
off
*0620#21 Repeti-
tive
Mon-
day
Friday 08:00 - Deactivate forwarding of
user 20
2Forwarding
of manager
on
*0620*2124 Repeti-
tive
Mon-
day
Friday 17:00 - Activate forwarding from
user 20 to user 24
3 Heater off #74 854 Single
execu-
tion
23.12.2014
22:00
- Deactivate control output
854 (e.g. heating)
4 Heater on *74 854 Single
execu-
tion
05/01/2015
05:30
- Activate control output
854 (e.g. heating)