Features
476
System functions and features as of R4.1
syd-0570/1.2 – R4.1 – 08.2016
Features and settings can also be activated, deactivated and modified with time control
and in parallel via terminals. Each particular status is event-controlled, i.e. the last
command chronologically determines the current status. The previous statuses of the
functions are not verified. If a function is removed from the table, its status is also re-
tained.
Note:
Invalid entries in the function column which cannot be executed do not trigger an error mes-
sage.
Switch Group Assignment
Each function can be assigned a switch group. This allows you, for example during hol-
iday periods, to activate or deactivate whole groups of functions. All functions with allo-
cation of the corresponding switch group are active on switch position 1 and inactive
on switch positions 2 + 3.
Tab. 317 Example of time-controlled functions with switch group assignment:
Note:
When switch groups are switched over, the functions are maintained in their status at the time.
Available Functions
All remote-controlled, user-specific features can be activated with time control. They
are activated with *06 <user No.>. For an overview of the available functions, see and
Tab. 3 1 3
. Moreover, the following functions can be activated with time control:
ID Name
Func-
tion
Mode
Start
day
Stop
day
Execution
date / time
Switch
group
assign-
ment
Meaning
5 Announce-
ment of
end of
work day
*931 02 Repeti-
tive
Mon-
day
Friday 07:00 7 Activate welcome announce-
ment 02 of the announcement
service
6Work
announce-
ment
#931 02 Repeti-
tive
Mon-
day
Friday 18:00 7 Deactivate welcome announce-
ment 02 of the announcement
service
7 Beginning
of Christ-
mas holi-
days
*85072 Single
execu-
tion
23.12.2014
16:00
Switching from switch group 7
to switch position 2:
All functions allocated switch
group 7 are deactivated.
8 End of
Christmas
holidays
*85071 Single
execu-
tion
05/01/2015
08:00
Switching from switch group 7
to switch position 1:
All functions allocated switch
group 7 are activated.

Table of Contents