Features
472
System functions and features as of R4.1
syd-0570/1.2 – R4.1 – 08.2016
• Terminal port
• SIP user name
• SIP password
• Transport protocol
• Language
Primary communication server
In der System configuration under Dual Homing ( =7t) you can define up to 10 pri-
mary communication servers. This setting is relevant if the communication server is
used as a backup communication server for Mitel 6700 SIP / 6800 SIP phones by
other primary communication servers.
See also:
Step-by-step instructions on how to set up Dual Homing, as well as more information about the
individual settings, are available in the WebAdmin online help.
9. 8 Remote control features
A large number of features can be remote controlled either from within or outside the
system:
• Remote controlling features from within the system:
User A activates / deactivates a feature on user B (Tab. 313)
• Remote controlling features from outside the system:
An integrated, external user A is dialled via a specially set call number in the com-
munication server (see ) and activates / deactivates a feature with user B (Tab. 313
)
or chooses a system-related feature.
Note:
The total number of digits dialled for each remote-controlled feature (for external remote
control as of *06) must not exceed 32 (with the remote control of *47 and long PINs for
example, this can be critical).
Tab. 313 User-related features remote-controlled from within and from outside the system
Feature Activate Reset
Clear configuration *00 or #00
Protect against / allow CFU/CFNR on own set *02 #02
Protect against / allow call waiting/intrusion on own set *04 #04
Activate / clear CFU *21 <Destination No.> #21
Activate / clear CFU Unconditional on user last configured *21# #21
Activate / deactivate presence status *27 <Profile No.> [hhmm]
[ddmm] #
#27 or *27 0 #
Activate / clear CFB *67 <Destination No.> #67