Tab. 10 Handling a CLIP number with NPI-type E.164
See also the examples in "Examples of CLIP Displays in the PISN", page 93.
Type of number
(TON)
Prefix Conversion
Unknown International prefix Prefix is truncated,
TON is set to International,
Further processing, see TON = International
National prefix Prefix is truncated,
TON is set to National
Further processing, see TON = National
No prefix CLIP number and TON remain unchanged
International Country code that matches the sepa-
rate PINX
Code is truncated,
TON is set to National
Further processing, see TON = National
No matching country code CLIP number and TON remain unchanged
National Long-distance code that matches the
separate PINX
Code is truncated,
TON is set to Subscriber.
No matching country code CLIP number and TON remain unchanged