Usage: Asynchronous command
CHANnel<m>:EATTenuation <ExtAtt>
Sets the attenuation of an external voltage divider that is part of the DUT before the
measuring point. The external attenuation is included in the measurement, and the
instrument shows the results that would be measured before the divider.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<ExtAtt> Values and unit depend on the selected scale (CHANnel<m>:
EATScale).
Range: Linear scale: 1E-3 to 1E+6, logarithmic scale: -60
dB to 120 dB
Increment: 0.01
*RST: 1
Usage: Asynchronous command
22.8.7.2 Micro button and R&S ProbeMeter
PROBe<m>:SETup:MODE........................................................................................... 1209
TRPRobe:SETup:DISPlaydiff.........................................................................................1211
PROBe<m>:SETup:DISPlaydiff......................................................................................1211
TRPRobe:PMETer:VISibility...........................................................................................1211
PROBe<m>:PMETer:VISibility....................................................................................... 1211
TRPRobe:PMETer:RESults:SINGle?.............................................................................. 1211
PROBe<m>:PMETer:RESults:SINGle?...........................................................................1211
TRPRobe:PMETer:RESults:COMMon?.......................................................................... 1212
PROBe<m>:PMETer:RESults:COMMon?....................................................................... 1212
TRPRobe:PMETer:RESults:DIFFerential?...................................................................... 1212
PROBe<m>:PMETer:RESults:DIFFerential?................................................................... 1212
TRPRobe:PMETer:RESults:NEGative?.......................................................................... 1213
PROBe<m>:PMETer:RESults:NEGative?....................................................................... 1213
TRPRobe:PMETer:RESults:POSitive?............................................................................1213
PROBe<m>:PMETer:RESults:POSitive?........................................................................ 1213
PROBe<m>:SETup:MODE <Mode>
Select the action that is started when you press the micro button on the probe head.
See also: "Micro button action" on page 168.
Acquisition and setup