33. Tunnelling
ROX™ v2.2 User Guide 377 RuggedBackbone™ RX1500
Figure 33.11. Connection form
If data is configured, the path to the Connection form will be tunnel/ipsec/connection/{line module}.
The Connection form is used for VPN connection configuration.
Connection Name
Synopsis: string - the keyword { default }
Synopsis: A string conforming to: "[A-Za-z][A-Za-z0-9#%_\-+.,]+"
The connection name. If the name is the default, this makes it the default setting for all connections.
Startup Operation
Synopsis: string - one of the following keywords { default, route, start, add, ignore }
Default: default
The action at IPSec startup time.
Authenticate By
Synopsis: string - one of the following keywords { secret, rsasig, default }
Default: default
The authentication method.
Connection Type
Synopsis: string - one of the following keywords { default, passthrough, transport, tunnel }
Default: default
The connection type. Tunnel signifies a host-to-host, host-to-subnet, or subnet-to-subnet tunnel;
transport signifies a host-to-host transport mode; passthrough signifies that no IPsec processing
should be done at all.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RuggedCom RuggedBackbone RX1500 and is the answer not in the manual?

RuggedCom RuggedBackbone RX1500 Specifications

General IconGeneral
Power SupplyDual redundant, hot-swappable power supplies
Switching CapacityUp to 128 Gbps
Operating Temperature Range-40°C to +85°C
MountingDIN rail or panel mount
CertificationsIEEE 1613, IEC 61850-3, EN 50155, EN 50121-4
Power Input24/48VDC or 110/220 VAC
EnclosureRugged metal
TypeModular Layer 3 switch