38. Firewall
ROX™ v2.2 User Guide 451 RuggedBackbone™ RX1500
Default: reject
A default action for connection establishment between different zones.
Log Level
Synopsis: string - one of the following keywords { emergency, alert, critical, error, warning,
notice, info, debug, none }
Default: none
(Optional) Whether or not logging will take place and at which logging level.
description
Synopsis: string
(Optional) The description string for this policy
Figure 38.18. Destination Zone form
destination-zone
The zone in which the request terminates. Enter a destination zone configuration by specifiying a
zone. Please choose either a pre-defined zone or all.
Figure 38.19. Source Zone form
source-zone
The zone from which the request originates. Enter a source zone configuration by specifiying a
zone. Please choose either a pre-defined zone or all.
38.5.7. Network Address Translation
Configuration of one-to-one Network Address Translation (NAT). The static network address translation
entries in this table can be used to set up a one-to-one correspondence between an external address
on your firewall and an RFC1918 address of a host behind the firewall. Static NAT is often used to allow
connections to an internal server from outside the network.
Figure 38.20. Net Address Translation Main Settings table

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RuggedCom RuggedBackbone RX1500 and is the answer not in the manual?

RuggedCom RuggedBackbone RX1500 Specifications

General IconGeneral
Power SupplyDual redundant, hot-swappable power supplies
Switching CapacityUp to 128 Gbps
Operating Temperature Range-40°C to +85°C
MountingDIN rail or panel mount
CertificationsIEEE 1613, IEC 61850-3, EN 50155, EN 50121-4
Power Input24/48VDC or 110/220 VAC
EnclosureRugged metal
TypeModular Layer 3 switch