8. Logging
ROX™ v2.2 User Guide 99 RuggedBackbone™ RX1500
Figure 8.6. Remote Server Selector form
name
Synopsis: integer
The log selector identifier. Enter an integer greater than 0; up to 8 selectors can be added. The log
selector determines which subsystem messages are included in the log.
negate
Excludes messages defined in the Remote Server Selector fields from the log. Selecting this option
acts as a logical NOT for the selector definition.
For example: Selecting same, debug, and mail in the Comparison, Level, and Facility-list fields
includes debug messages from the mail subsystem in the log. Selecting Negate excludes debug
messages from the mail subsystem from the log.
comparison
Synopsis: string - one of the following keywords { same, same_or_higher }
Default: same_or_higher
The message severity levels to include in the log:
same: includes only messages of the severity level selected in the Level field.
same_or_higher: includes messages of the severity level selected in the Level field, and all
messages of higher severity.
For example:
Selecting debug in the Level field and same in the Comparison field includes only debug
messages in the log.
Selecting debug in the Level field and same_or_higher in the Comparison field includes debug
and all higher severity messages in the log.
level
Synopsis: string - one of the following keywords { all, none, debug, info, notice, warning, err, crit,
alert, emerg }
Default: all
The base message severity level to include in the log. all includes all messages. none excludes all
messages. Other levels are listed in order of increasing severity.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RuggedCom RuggedBackbone RX1500 and is the answer not in the manual?

RuggedCom RuggedBackbone RX1500 Specifications

General IconGeneral
Power SupplyDual redundant, hot-swappable power supplies
Switching CapacityUp to 128 Gbps
Operating Temperature Range-40°C to +85°C
MountingDIN rail or panel mount
CertificationsIEEE 1613, IEC 61850-3, EN 50155, EN 50121-4
Power Input24/48VDC or 110/220 VAC
EnclosureRugged metal
TypeModular Layer 3 switch

Related product manuals