6. Alarms
ROX™ v2.2 User Guide 93 RuggedBackbone™ RX1500
6.2.1. Administrative Alarm Configuration
Figure 6.9. Admin Alarm Configuration table
The path to the Admin Alarm Configuration table is admin/alarm-config/admin.
Figure 6.10. Admin Alarm Configuration form
The path to the Admin Alarm Configuration form is admin/alarm-config/admin/{alarm id}.
id
Synopsis: integer
This is the ID number of the alarm assigned by the system.
description
Synopsis: A string
The name of the alarm.
severity
Synopsis: string - one of the following keywords { debug, info, notice, warning, error, critical,
alert, emergency }
The severity level can be one of emergency, alert, critical, error, warning, notice, info, and debug.
This cannot be changed for some alarms
admin-enable
If disabled, the alarm is not reported in the active list and does not actuate led/failrelay.
failrelay-enable
If enabled, this alarm will assert the failrelay.
led-enable
If enabled, the main 'Alarm' LED light will be red when this alarm is asserted. If disabled, the main
'Alarm' LED light is not affected by this alarm.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RuggedCom RuggedBackbone RX1500 and is the answer not in the manual?

RuggedCom RuggedBackbone RX1500 Specifications

General IconGeneral
Power SupplyDual redundant, hot-swappable power supplies
Switching CapacityUp to 128 Gbps
Operating Temperature Range-40°C to +85°C
MountingDIN rail or panel mount
CertificationsIEEE 1613, IEC 61850-3, EN 50155, EN 50121-4
Power Input24/48VDC or 110/220 VAC
EnclosureRugged metal
TypeModular Layer 3 switch