Parameters
Introduction to Parameters
1-12
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Can be changed
Inverter state in which the parameter is changeable. Three states are possible:
This indicates when the parameter can be changed. One, two or all three states
may be specified. If all three states are specified, this means that it is possible to
change this parameter setting in all three inverter states. (x) shows, that the
parameter is only changeable when p0010 = x.
Data Set
Parameters which are dependent on a data set are identified as follows:
CDS (Command Data Set)
They are always indexed with [0 ... n] with n = 0 ... 3 depending on setting in
p0170.
[0] = Command Data Set 0
[1] = Command Data Set 1
etc.
DDS (Drive Data Set)
They are always indexed with [0 ... n] with n = 0 ... 3 depending on setting in
p0180.
[0] = Drive Data Set 0
[1] = Drive Data Set 1
etc.
MDS (Motor Data Set) and PDS (Power unit Data Set)
They are always indexed with [0 ... n] with n = 0 ... 3 depending on setting in
p0180). The Motor Data Sets and Power unit Data Sets are allocated to the Drive
Data Sets, i.e. they are automatically addressed with the selection of a Drive Data
Set (e.g. Drive Data Set 1 includes Motor Data Set 1 and Power unit Data Set 1).
Data sets can only be applied and cleared when p0010 = 15 is set.
Commissioning C(x)
Run U
Ready to runt T

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU230P-2 DP and is the answer not in the manual?

Siemens CU230P-2 DP Specifications

General IconGeneral
BrandSiemens
ModelCU230P-2 DP
CategoryControl Unit
LanguageEnglish

Related product manuals