Connector/Binector (BICO)-Parameters
Parameters
1-419
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
1.4 Connector/Binector (BICO)-Parameters
1.4.1 Binector Input Parameters
Product: SINAMICS G120, Version: 4301300, Language: eng, Type: BI
p0730 BI: CU signal source for terminal DO 0 / CU S_src DO 0
p0731 BI: CU signal source for terminal DO 1 / CU S_src DO 1
p0732 BI: CU signal source for terminal DO 2 / CU S_src DO 2
p0782[0...1] BI: CU analog outputs signal source for inversion / CU AO invert
p0806 BI: Inhibit master control / PcCtrl inhibit
p0810 BI: Command Data Set selection CDS bit 0 / CDS select., bit 0
p0811 BI: Command data set selection CDS bit 1 / CDS select., bit 1
p0820[0...n] BI: Drive Data Set selection DDS bit 0 / DDS select., bit 0
p0821[0...n] BI: Drive Data Set selection DDS bit 1 / DDS select., bit 1
p0840[0...n] BI: ON/OFF1 / ON/OFF1
p0844[0...n] BI: 1. OFF2 / 1. OFF2
p0845[0...n] BI: 2. OFF2 / 2. OFF2
p0848[0...n] BI: 1. OFF3 / 1. OFF3
p0849[0...n] BI: 2. OFF3 / 2. OFF3
p0852[0...n] BI: Operation enable / Operation enable
p0854[0...n] BI: Master ctrl by PLC / Master ctrl by PLC
p1020[0...n] BI: Fixed speed setpoint selection Bit 0 / n_set_fixed Bit 0
p1021[0...n] BI: Fixed speed setpoint selection Bit 1 / n_set_fixed Bit 1
p1022[0...n] BI: Fixed speed setpoint selection Bit 2 / n_set_fixed Bit 2
p1023[0...n] BI: Fixed speed setpoint selection Bit 3 / n_set_fixed Bit 3
p1035[0...n] BI: Motorized potentiometer setpoint raise / Mop raise
p1036[0...n] BI: Motorized potentiometer lower setpoint / Mop lower
p1039[0...n] BI: Motorized potentiometer inversion / Mop inversion
p1041[0...n] BI: Motorized potentiometer manual/automatic / Mop manual/auto
p1043[0...n] BI: Motorized potentiometer accept setpoint / Mop accept set val
p1055[0...n] BI: Jog bit 0 / Jog bit 0
p1056[0...n] BI: Jog bit 1 / Jog bit 1
p1108[0...n] BI: Total setpoint selection / Total setp sel
p1110[0...n] BI: Inhibit negative direction / Inhib neg dir
p1111[0...n] BI: Inhibit positive direction / Inhib pos dir
p1113[0...n] BI: Setpoint inversion / Setp inv
p1122[0...n] BI: Bypass ramp-function generator / Bypass RFG
p1140[0...n] BI: Ramp-function generator enable / RFG enable
p1141[0...n] BI: Continue ramp-function generator / Continue RFG
p1142[0...n] BI: Speed setpoint enable / n_set enable
p1143[0...n] BI: Ramp-function generator, accept setting value / Accept RFG set val
p1201[0...n] BI: Flying restart enable signal source / Fly_res enab S_src
p1230[0...n] BI: DC brake activation / DC brake active
p1266 BI: Bypass, control command / Bypass command
p1269[0...1] BI: Bypass switch feedback signal / Bypass FS
p1476[0...n] BI: Speed controller hold integrator / n_ctrl integ stop
p1477[0...n] BI: Speed controller set integrator value / n_ctrl integ set
p1492[0...n] BI: Droop feedback enable / Droop enable
p1501[0...n] BI: Change over between closed-loop speed/torque control / Changeov n/M_ctrl
p2080[0...15] BI: Binector-connector converter status word 1 / Bin/con ZSW1
p2081[0...15] BI: Binector-connector converter status word 2 / Bin/con ZSW2
p2082[0...15] BI: Binector-connector converter status word 3 / Bin/con ZSW3