Parameters
List of Parameters
1-220
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description: Displays the nominal stator inductance identified for the 3rd point of the saturation characteristic.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the nominal stator inductance identified for the 4th point of the saturation characteristic.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the identified IGBT threshold voltage.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the identified effective valve lockout time.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the identified rotor resistance
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
r1918[0...2] Identified stator inductance 3 / L_stator 3 ident
Access level: 4 Calculated: - Data type: FloatingPoint32
Unit: [mH] Scaling: - Data set: -
r1919[0...2] Identified stator inductance 4 / L_stator 4 ident
Access level: 4 Calculated: - Data type: FloatingPoint32
Unit: [mH] Scaling: - Data set: -
r1925[0...2] Identified threshold voltage / V_threshold ident
Access level: 4 Calculated: - Data type: FloatingPoint32
Unit: [Vrms] Scaling: - Data set: -
r1926[0...2] Identified effective valve lockout time / t_lock_valve id
Access level: 4 Calculated: - Data type: FloatingPoint32
Unit: [µs] Scaling: - Data set: -
r1927[0...2] Identified rotor resistance / R_rotor ident
Access level: 4 Calculated: - Data type: FloatingPoint32
Unit: [Ohm] Scaling: - Data set: -