Parameters
List of Parameters
1-380
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description: Setting parameter for the run-time group in which the instance BSW 1 of the binary changeover switch is to be
called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance BSW 1 within the run-time group set in p20216.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities X0 and X1 of instance NSW 0 of the numeric changeover switch.
Index: [0] = Input X0
[1] = Input X1
Description: Sets the signal source of the switch setting I of instance NSW 0 of the numeric changeover switch.
Description: Display parameter for output quantity Y of instance NSW 0 of the numeric changeover switch.
Description: Setting parameter for the run-time group in which the instance NSW 0 of the numeric changeover switch is to be
called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
p20216 BSW 1 run-time group / BSW 1 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
1 9999 9999
p20217 BSW 1 run sequence / BSW 1 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
0 7999 590
p20218[0...1] CI: NSW 0 inputs / NSW 0 inputs
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Data set: -
Min Max Factory setting
- - 0
p20219 BI: NSW 0 switch setting I / NSW 0 sw_setting
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
- - 0
r20220 CO: NSW 0 output Y / NSW 0 output Y
Access level: 3 Calculated: - Data type: FloatingPoint32
Unit: - Scaling: PERCENT Data set: -
p20221 NSW 0 run-time group / NSW 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
5 9999 9999