SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description: Sets the signal source for input pulse I and the reset input R of instance PST 1 of the pulse extension element.
Index: [0] = Input pulse I
[1] = Reset input R
Description: Setting parameter for pulse duration T in milliseconds of instance PST 1 of the pulse extension element.
Description: Display parameter for output pulse Q of instance PST 1 of the pulse extension element.
Description: Setting parameter for the run-time group in which the instance PST 1 of the pulse extension element is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance PST 1 within the run-time group set in p20186.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for set input S and reset input R of instance RSR 0 of the RS flipflop.
Index: [0] = Set S
[1] = Reset R
p20183[0...1] BI: PST 1 inputs / PST 1 inputs
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
- - 0
p20184 PST 1 pulse duration in ms / PST 1 pulse_dur ms
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
0.00 60000.00 0.00
r20185 BO: PST 1 output Q / PST 1 output Q
Access level: 3 Calculated: - Data type: Unsigned32
Unit: - Scaling: - Data set: -
p20186 PST 1 run-time group / PST 1 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
5 9999 9999
p20187 PST 1 run sequence / PST 1 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
0 7999 500
p20188[0...1] BI: RSR 0 inputs / RSR 0 inputs
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
- - 0