List of Parameters
Parameters
1-373
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description: Setting parameter for the run sequence of instance PDF 1 within the run-time group set in p20176.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for input pulse I and the reset input R of instance PST 0 of the pulse extension element.
Index: [0] = Input pulse I
[1] = Reset input R
Description: Setting parameter for pulse duration T in milliseconds of instance PST 0 of the pulse extension element.
Description: Display parameter for output pulse Q of instance PST 0 of the pulse extension element.
Description: Setting parameter for the run-time group in which the instance PST 0 of the pulse extension element is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance PST 0 within the run-time group set in p20181.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20177 PDF 1 run sequence / PDF 1 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
0 32000 470
p20178[0...1] BI: PST 0 inputs / PST 0 inputs
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
- - 0
p20179 PST 0 pulse duration in ms / PST 0 pulse_dur ms
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
0.00 60000.00 0.00
r20180 BO: PST 0 output Q / PST 0 output Q
Access level: 3 Calculated: - Data type: Unsigned32
Unit: - Scaling: - Data set: -
p20181 PST 0 run-time group / PST 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
5 9999 9999
p20182 PST 0 run sequence / PST 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Data set: -
Min Max Factory setting
0 7999 490