Parameters
List of Parameters
1-36
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description: Displays the BIOS and EEPROM data version.
Re r0198[0]
Displays the BIOS version.
Re r0198[1]
Displays the EEPROM data version.
Dependency: Refer to: r0018, r0197
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Freely assignable name for a drive object.
In the commissioning software, this name cannot be entered using the expert list, but is specified in the configura-
tion assistant. The object name can be subsequently modified in the Project Navigator using standard Windows
resources.
Note: The parameter is not influenced by setting the factory setting.
Description: Displays the unique code number of the power unit.
Note: r0200 = 0: No power unit data found
Description: Sets the actual code number from r0200 to acknowledge the power unit being used.
When commissioned for the first time, the code number is automatically transferred from r0200 into p0201.
Note: The parameter is used to identify when the drive is being commissioned for the first time.
The power unit commissioning can only be exited (p0201 = r0200), if the actual and acknowledged code numbers
are identical (p0010 = 2).
When the code number is changed, the connection voltage (p0210) is checked and, if necessary, adjusted.
r0198[0...1] BIOS and EEPROM data version / BIOS/EEPROM vers
Access level: 4 Calculated: - Data type: Unsigned32
Unit: - Scaling: - Data set: -
p0199[0...24] Drive object name / DO name
Access level: 4 Calculated: - Data type: Unsigned16
Can be changed: C Scaling: - Data set: -
Min Max Factory setting
0 65535 0
r0200[0...n] Power unit code number actual / PU code no. act
Access level: 3 Calculated: - Data type: Unsigned16
Unit: - Scaling: - Data set: PDS
p0201[0...n] Power unit code number / PU code no
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: C(2) Scaling: - Data set: PDS
Min Max Factory setting
0 65535 0