8. TROUBLESHOOTING
8 - 9
No.
Name
Detail
No.
Detail name
Stop
Type
(Note 2,
3)
Alarm
deactivation
Alarm code
Alarm
reset
Cycling
the
power
ACD3
(Bit 3)
ACD2
(Bit 2)
ACD1
(Bit 1)
ACD0
(Bit 0)
Alarm
71.1
Load-side encoder normal
communication - Receive data
error 1
EDB
71.2
Load-side encoder normal
communication - Receive data
error 2
EDB
71.3
Load-side encoder normal
communication - Receive data
error 3
EDB
71
Load-side encoder
normal
communication
error 1
71.5
Load-side encoder normal
communication - Transmission
data error 1
EDB
0
1
1
0
71.6
Load-side encoder normal
communication - Transmission
data error 2
EDB
71.7
Load-side encoder normal
communication - Transmission
data error 3
EDB
71.9
Load-side encoder normal
communication - Receive data
error 4
EDB
71.A
Load-side encoder normal
communication - Receive data
error 5
EDB
72
Load-side encoder
normal
communication
error 2
72.1
Load-side encoder data error 1
EDB
0
1
1
0
72.2
Load-side encoder data update
error
EDB
72.3
Load-side encoder data
waveform error
EDB
72.4
Load-side encoder non-signal
error
EDB
72.5
Load-side encoder hardware
error 1
EDB
72.6
Load-side encoder hardware
error 2
EDB
72.9
Load-side encoder data error 2
EDB
74
Option card error 1
74.1
Option card error 1
DB
74.2
Option card error 2
DB
74.3
Option card error 3
DB
74.4
Option card error 4
DB
74.5
Option card error 5
DB
75
Option card error 2
75.3
Option card connection error
EDB
75.4
Option card disconnected
DB
79
Functional safety
unit diagnosis error
79.1
Functional safety unit power
voltage error
DB
(Note 5)
1
1
1
1
79.2
Functional safety unit internal
error
DB
79.3
Abnormal temperature of
functional safety unit
SD
(Note 5)
79.4
Driver error
SD
79.5
Input device error
SD
79.6
Output device error
SD
79.7
Mismatched input signal error
SD
79.8
Position feedback fixing error
DB
7A
Parameter setting
error (safety
observation function)
7A.1
Parameter verification error
(safety observation function)
DB
1
0
0
0
7A.2
Parameter setting range error
(safety observation function)
DB
7A.3
Parameter combination error
(safety observation function)
DB
7A.4
Functional safety unit
combination error (safety
observation function)
DB