16 - 258
16. POSITIONING MODE
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP
CL
PS
PA26
*AOP5
Function
selection A-5
_ _ _ x
Torque limit function selection at instantaneous power failure (instantaneous power
failure tough drive selection)
0: Disabled
1: Enabled
When an instantaneous power failure occurs during operation, you can save electric
energy charged in the capacitor in the driver by limiting torque at acceleration. You
can also delay the time until [AL. 10.2 Voltage drop in the main circuit power] occurs
with instantaneous power failure tough drive function. Doing this will enable you to
set a longer time in [Pr. PF25 SEMI-F47 function - Instantaneous power failure
detection time].
The torque limit function at instantaneous power failure is enabled when "SEMI-F47
function selection" in [Pr. PA20] is "Enabled (_ 1 _ _)".
0h
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h