Lower limit value of each parameter setting range
Reads the permissible lower limit values of the parameters in the parameter
group specified with the command [8] [5] + data No. [0] [0]. Before reading the
lower limit values, therefore, always specify the parameter group with the
command [8] [5] + data No. [0] [0].
The decimal equivalent of the data No. (hexadecimal) value corresponds to the
parameter No.
Each parameter symbol
Reads the symbols of the parameters in the parameter group specified with the
command [8] [5] + data No. [0] [0]. Before reading the symbols, therefore,
always specify the parameter group with the command [8] [5] + data No. [0] [0].
The decimal equivalent of the data No. (hexadecimal) value corresponds to the
parameter No.
Writing enable/disable of parameters
Reads writing enable/disable of the parameters in the parameter group
specified with the command [8] [5] + data No. [0] [0]. Before reading writing
enable/disable, therefore, always specify the parameter group with the
command [8] [5] + data No. [0] [0].
0000: Writing enabled
0001: Writing disabled
(3) External I/O signals (command [1] [2])
External input pin status
Status of input device turned on by communication
External output pin status
(4) Current position latch display (command [1] [A])
MSD (Mark detection) rising latch data (data part)
MSD (Mark detection) falling latch data (data part)
MSD (Mark detection) rising latch data (data part + additional information)