70 - Maintenance Procedures
4. Examine the threaded insert for correct installation
Do a check of the insertion properties.
For threaded inserts per LN 9039 (non–
locking):
It must be possible to install the threaded
insert without a tool.
For inserts per LN 9499 (screw locking):
The threaded insert must not rotate.
Use the fastener or an internal limit
gauge.
Make sure that the threaded insert does not
rotate when you screw the bolt.
- If the threaded insert rotates, secure
the insert with Loctite.
Refer to Paragraph 6 for the
procedure how to safety the
threaded inserts.
Remove all the remaining anti-corrosion agent,
sealant or adhesive.
Measure the insertion depth x (both sides in
the case of through holes).
Make sure that the tang is removed.
5. Remove the threaded inserts
Permitted only if specified for the damaged threaded inserts!
To remove a threaded insert, select a
manufacturer’s removal tool that is applicable
to the internal thread diameter of the insert.
- Move this tool into the insert in a tight
fit.
Turn the tool counterclockwise under constant
pressure.
The insert must be removed.
If a new threaded insert of the same size is
installed, recut the thread.