E4 Series
Maintenance Manual
Starting
Page 204
E4.08.04
Rev. 29
80 - Maintenance Procedures
01-Jul-2020
3. Glow System
A. Examine the Glow Plug Control Unit (GPC)
Detail Steps/Work Items
Key Items/References
(1)
Examine the GPC (new version) for:
- Incorrect sealing
- Unequal clearance between housing
panels
- Signs of leakage or humidity in the
GPC.
Refer to Fig. 80 - 3 and Fig. 80 - 4.
Fig. 80 - 3 Not permitted (clearance at points [1] and [2] not equal)
Fig. 80 - 4 Not permitted (possible leakage)
1
2