E4 Series
Maintenance Manual
Starting
E4.08.04
Rev. 29
Page 101
80 -Troubleshooting
01-Jul-2020
Troubleshooting Information
1. General
The table below lists the possible defects of the Starting system. If you have the trouble detailed in
the Trouble column, read across to the Possible Cause column. Then do the repair in the Repair
column.
Trouble
Possible Cause
Repair
The starter does not operate
The starter relay is defective.
Replace the starter.
The starter receives no electric
power.
Refer to Aircraft Maintenance
Manual.
Starter defective
Replace the starter.
Caution lamp active for GPC
(if installed)
Defective glow plug
Measure resistance of each
glow plug:
- if resistance is infinitely,
replace the glow plug
Examine the defective glow
plug for:
- any kind of physical
damage
- broken parts
If you find broken parts,
contact Austro Engine GmbH.
Defective water temperature
sensor
Replace the water temperature
sensor.

Table of Contents

Other manuals for Austro Engine E4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Austro Engine E4 Series and is the answer not in the manual?

Austro Engine E4 Series Specifications

General IconGeneral
BrandAustro Engine
ModelE4 Series
CategoryEngine
LanguageEnglish

Related product manuals