71 - Maintenance Procedures
Connect the CAS2 branch to sensor.
Refer to Fig. 71 - 87 and Fig. 71 - 88.
Connect the pigtail of CAS2 to the blade
terminal installed with CAS1.
Connect the pigtail of CAS1 to the pigtail of
CAS2 (double connector).
Install the BPA blade terminal [11] with the
BPA mounting screw.
Apply Loctite 243.
Refer to Fig. 71 - 90.
Connect the pigtail of the BPA to the blade
terminal of the BPA.
Attach the branch of BPA and CAS2 to the
BPA housing.
Use the edge clip No.[06] and cable tie
No.[05]
Only the cable tie is permitted for connector adapter (of BPA filter)
attachment.
Do not tighten the BPA hose with too much force!