Page 309
85-Maintenance Procedures
01-Jul-2020
Detail Steps/Work Items
Key Items/References
ï‚· Move the Power lever to Max. Continuous Power
ï‚· Record 30s on ECU A, then 30s on ECU B
ï‚· Move the Power lever to Idle and stop LiveView-Recording
ï‚· Collect and keep the data recorded after the cylinder head replacement
ï‚· Send the data collected before and after cylinder head replacement to Austro
Engine GmbH.
Estimated results:
ï‚· Total self-test runtime before/after almost the same (same engine power after the
cylinder head replacement)
ï‚· At Max Continuous Power almost the same rates of boost pressure actuation (intake
and exhaust air-tight)
ï‚· Smooth engine run on ECU B (camshaft system correctly configured).
Austro Engine GmbH will do a check of the data collected after the power
analysis to make sure that no power loss occurred and to determine the
airworthiness.