240
Temperature 0°C to 40°C
Humidity 30% to 90% (no condensation)
Power 100VAC to 240 VAC ±10%, 50/60Hz
Consumption HVS-390HS: 510 W (at 100-120 VAC) 460 W (at 220-240 VAC)
HVS-391OU: 32 W (at 100-120 VAC) 30 W (at 220-240 VAC)
Dimensions HVS-390HS: 430 (W) x 450 (D) x 132 (H) mm
HVS-391OU: 576 (W) x 279 (D) x 131 (H) mm
Weight HVS-390HS: 17 kg (in Standard), 20 kg (in Full Option)
HVS-391OU: 5.5 kg
Consumables HVS-390HS: Power supply unit. Replace every 5 years.
Cooling fan. Replace every 4 years
HVS-391OU: Power supply unit. Replace every 6 years.
Accessories Manual, AC cord, Rack mount brackets and BNC cable (10 m)
Options ◇HVS-30HSDI: SDI Input card w/ up-resize engine
◇HVS-30HSDI-A: SDI Input card w/o up-resize engine
◇HVS-30HSAI: Analog Input card
◇HVS-30PCIN: PC Input card
◇HVS-30HSDO: SDI Output card
◇HVS-30HSAO: Analog Output card
◇HVS-30PCO: PC Output card
◇HVS-30TALR: Tally Relay Output card (18-output)
◇HVS-30EXTME: M/E Expansion card
◇HVS-39ED: Editor Interface software
◇HVS-39MEM: Clip Memory Expansion card
◇HVS-39MB: Still and Clip Backup Memory
◇HVS-39VR: Virtual Link software
◇HVS-39PSM: Redundant Power Supply Unit for Main Unit
◇HVS-39PSO: Redundant Power Supply Unit for Operation Unit
◇HVS-AUX8/16/32: AUX Remote Control Unit
◇HVS-TALR20/32: Tally Relay Output unit (20/32-output)
◇HVS-TALOC20/32: Tally Open Collector Output unit (20/32-output)

Table of Contents