EasyManuals Logo

Fujitsu PRIMERGY RX2540 M6 Upgrade And Maintenance Manual

Fujitsu PRIMERGY RX2540 M6
680 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #169 background imageLoading...
Page #169 background image
RAID level Procedure
RAID 0
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all
data are lost!
RAID 1
RAID 5
Removing an HDD/SSD module from a RAID 1 or
RAID 5 array will not result in data loss. However
,
the removed drive needs to be replaced
immediately by an HDD/SSD module of the same
or larger capacity
.
After replacing the HDD/SSD module,
RAID rebuild will be performed as a
background process, see "Performing a
RAID array rebuild" on page 106
.
In order to permanently remove an operational HDD/SSD module that is part of
a RAID array from the server, you first need to delete the array using
ServerV
iew RAID Manager.
CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
â–¶
Be sure to back up your data before deleting a RAID array.
â–¶
For more information, see the "ServerView Suite RAID
Management" user guide.
Removing a 2.5-inch HDD/SSD module
â–¶
Pinch the green locking clips and open the locking lever
, see Figure 76.
â–¶
Pull the HDD/SSD module out a few centimeters.
â–¶
W
ait about 30 seconds.
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
This period is necessary for the RAID controller to recognize that an
SSD module has been removed.
Hard disk drive (HDD) / solid state disk (SSD)
RX2540 M6 Upgrade and Maintenance Manual 169

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2540 M6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2540 M6 and is the answer not in the manual?

Fujitsu PRIMERGY RX2540 M6 Specifications

General IconGeneral
Memory Slots32 DIMM slots
Form Factor2U rack server
ProcessorIntel Xeon Scalable Processors (3rd generation)
StorageUp to 24 x 2.5" or 12 x 3.5" drives
RAID SupportRAID 0, 1, 5, 6, 10
Network4 x 1GbE ports (onboard), optional 10/25GbE
Power Supply800 W, 1200 W, 1600 W
Expansion SlotsUp to 8x PCIe Gen4 slots
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
ManagementiRMC S5