8 Fans
8.1 Safety notes
CAUTION
â–¶
Do not damage or modify internal cables or devices. Doing so may
cause a device failure, fire, or electric shock.
â–¶
Devices and components inside the server remain hot after
shutdown. After shutting down the server, wait for hot components
to cool down before installing or removing internal options.
â–¶
Circuit boards and soldered parts of internal options are exposed
and can be damaged by static electricity. Always discharge static
build-up (e.g. by touching a grounded object) before handling
electrostatic-sensitive devices (ESDs).
â–¶
Do not touch the circuitry on boards or soldered parts. Hold circuit
boards by their metallic areas or edges.
â–¶
If devices are installed or disassembled using methods other than
those outlined in this chapter, the warranty will be invalidated.
â–¶
The procedure of installation on this notes might change depending
on a configuration of options.
â–¶
For more information, see "Important information" on page 35
.
8.2 Basic information
Base units are supplied with three hot-plug fan modules (1 CPU configuration)
or six hot-plug fan modules (2 CPU configuration).
Base units with three fan modules operate in a 1 of 3 redundancy, base units
with six fan modules operate in a 1 of 6 redundancy
. In other words, if one of
the three or six fan modules fails, the system will operate without any problem.
The failed fan module can be exchanged without shutting down the server (hot-
plug).
There are dual rotor fan types installed.
RX2540 M6 Upgrade and Maintenance Manual 227

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2540 M6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2540 M6 and is the answer not in the manual?

Fujitsu PRIMERGY RX2540 M6 Specifications

General IconGeneral
Memory Slots32 DIMM slots
Form Factor2U rack server
ProcessorIntel Xeon Scalable Processors (3rd generation)
StorageUp to 24 x 2.5" or 12 x 3.5" drives
RAID SupportRAID 0, 1, 5, 6, 10
Network4 x 1GbE ports (onboard), optional 10/25GbE
Power Supply800 W, 1200 W, 1600 W
Expansion SlotsUp to 8x PCIe Gen4 slots
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
ManagementiRMC S5

Related product manuals