Page #66 background imageLoading...
Page #66 background image
Figure 15: Locking the cable clamp of a PSU
â–¶
Pull the cable clamp up (1).
â–¶
Thread the power cord through the cable clamp (2).
â–¶
Press the cable clamp down until it engages to secure the cable (3).
It will take about 60 seconds until the server can be powered on.
4.7.2 Connecting the power cord (DC PSU)
Example DC PSU -48 V
CAUTION
The DC PSU adjusts automatically to any mains voltage in the range
from -40.5 V - -57 V.
â–¶
Y
ou may only operate the server if its rated voltage range
corresponds to the local mains voltage.
Basic hardware procedures
66 Upgrade and Maintenance Manual RX2540 M6

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2540 M6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2540 M6 and is the answer not in the manual?

Fujitsu PRIMERGY RX2540 M6 Specifications

General IconGeneral
Memory Slots32 DIMM slots
Form Factor2U rack server
ProcessorIntel Xeon Scalable Processors (3rd generation)
StorageUp to 24 x 2.5" or 12 x 3.5" drives
RAID SupportRAID 0, 1, 5, 6, 10
Network4 x 1GbE ports (onboard), optional 10/25GbE
Power Supply800 W, 1200 W, 1600 W
Expansion SlotsUp to 8x PCIe Gen4 slots
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
ManagementiRMC S5