Power-on indicator / AC connected indicator (2)
Status Description
off The server is switched off and not connected to the
mains.
green on The server is switched on.
flashing white The iRMC firmware is starting up after the server has
been connected to the mains.
white on The server is switched off and connected to the mains
(standby mode).
After connecting the server to the mains, it
will take about 60 seconds until the server
will enter standby mode and can be switched
on.
exchange flashing
green and white
The server has been switched on but Power Cycle
Delay settings delay it from turning on for a specified
time.
CSS indicator (3)
Status Description
off No critical event detected (CSS component).
orange on Prefailure event detected (CSS component).
For HDDs, see also "HDD prefailure detection" on
page 551
.
flashing orange CSS component failure detected.
Global Error indicator (4)
See also "iRMC-related status signals" on page 551.
Status Description
of
f No critical event detected (non-CSS component).
orange on Prefailure event detected (non-CSS component).
Appendix A
550 Upgrade and Maintenance Manual RX2540 M6