1126800 SmartPAC 2 with WPC Integration
page 312 Chapter 5 SmartPAC 2 Program Mode
When you are done with the setting, here is an example of how your display would look
like. (the settings here are 185° auto on, 220° auto off):
arc moves around
"circle diagram"
as you press
cursor keys
to set timing
angles when
cam channel
turns on and off
0
90
180
270
USE THE L/R CURSOR
KEYS TO SET THE
ON ANGLE. USE THE
U/D CURSOR KEYS TO
SET THE OFF ANGLE.
PRESS THE RESET
KEY WHEN DONE.
TOOL NUMBER 1234567
CHAIR BRACKET
CHANNEL 1
UNNAMED
ON 185
OFF 220
DWELL 35
AUTO
Figure 5 - 36. An Auto Advance Channel
4. Press RESET to go back to the list of channel names.
Setting DSV ON Channel Timing
When you want a channel to stay on all the time that the press is running, plus perhaps, a
while longer, use the DSV ON cam timing. The channel will turn on when dual safety valve
(DSV) goes on and the press starts running, and turn off some time after the DSV goes off.
The setting you make is the length of time the cam stays on after the DSV valve goes off.
DSV ON timing is useful for controlling conveyors and other accessories.
1. Select “Program DSV On” in the cam type menu (Figure 5 - 30).