1126800 SmartPAC 2 with WPC Integration
Page 412 Chapter 7 SmartPAC 2 Fault Messages
Messages displayed for programming problems
These messages tell you that there is a problem with the tool number or that a tool number is
not properly loaded. These messages may indicate an internal problem with SmartPAC 2
itself.
If you cannot correct the problem yourself after reading the remedy for the problem below,
contact Wintriss Tech Support for assistance.
After you have corrected the problem, press RESET. If the problem is corrected, you will be
able to run the press again. If not, you will get the same fault message.
"No tool number has been loaded"
Explanation: A tool number is not presently loaded. You will see this message if you
try to go into Run mode without a tool number loaded. A tool number
must be loaded before entering Run mode.
Remedy: Turn the Program/Run key to "Program,” and then press RESET. Now
you can program and load the appropriate tool number in Program mode.