SmartPAC 2 with WPC Integration 1126800
Installing SmartPAC 2 and WPC Chapter 2 page 75
Table 2 - 3. Resolver Wiring on SmartPAC 2
PIN # on TB101 Wire Color
Shield
[terminate to ground stud
nearest entry to enclosure]
212 (GND)
no connection
213 (S1) Black*
214 (S2) Green
215 (R1) Red
216 (S3) Yellow*
217 (R2) Orange
218 (S4) Brown
* Shown for clockwise rotation, facing shaft.
For counterclockwise, swap black and yellow wires
Connecting Communications Between SmartPAC 2 and WPC
1. Locate TB105 on the SmartPAC 2 board (Figure 2 - 39, page 162) and TB501 on the
WPC Interface Board (Figure 2 - 38, page 161). See Figure 1 at the end of this manual
for wiring.
2. Run the four-conductor shielded cable through the same flexible liquid-tight low-
voltage conduit (referenced above) from SmartPAC to WPC.